Skip to the number
YardsNeeded

Concrete footing calculator: how big should a concrete footing be?

19 × 6 in footing

4.11 cubic yards of concrete, or 185 bags of 80 lb · Table R403.1(1) at 1,500 psf · for 2 stories over a basement, 140 ft of wall

Run your own numbers

Enter it the way you measured it: 4.5, 4 1/2, 3/8 or 10' 6".

19 × 6 in footing

4.11 cubic yards of concrete, or 185 bags of 80 lb · Table R403.1(1) at 1,500 psf

    Source: IRC 2021 Section R403.1.1 and Table R403.1(1), Minimum Width and Thickness for Concrete Footings for Light-Frame Construction, with Table R401.4.1 (International Code Council), read October 31, 2026. Read the source

    A two-story light-frame house over a basement, on 1,500 psf clay with 25 psf of ground snow, needs a concrete wall footing of at least 19 × 6 in by IRC 2021 Table R403.1(1): 4.11 cubic yards for 140 ft.

    A worked example

    A 3 story house over a crawl space, 36 ft wide, under 50 psf of ground snow, on soil a report puts at 1,750 psf, with 112 ft of footing poured from 60 lb bags, needs a 20 × 7 in footing, 4.04 cubic yards. The 50 psf, 3 story crawl space row of Table R403.1(1) gives 20 × 6 in at 1,500 psf and 15 × 6 at 2,000. At 1,750 the width interpolates to 17.5 in, rounded up to 18. The house is 4 ft wider than the table's 32: 2 in wider and 1 in thicker, 20 × 7. 112 ft of it is 108.9 cu ft: 4.04 cubic yards, or 242 bags of 60 lb.

    How big should a concrete footing be?

    At least 12 in wide and 6 in thick under any house wall, by IRC 2021 Section R403.1.1. On 1,500 psf clay with 20 psf of roof load, a 1 story house on a slab stays at 12 × 6, a 2 story over a basement needs 19 × 6, and a 3 story over a basement under 70 psf of snow 24 × 8.

    How thick should a concrete footing be?

    6 in in nearly every row of Table R403.1(1). Only on 1,500 psf soil does it reach 7 in, for a 3 story basement at 20 or 30 psf, a 2 story basement at 50 or 70 psf and a 3 story crawl space at 70 psf, or 8 in, for a 3 story basement at 50 or 70 psf. A house wider than 32 ft adds 1 in for every 4 ft.

    How deep should a concrete footing be?

    Its bottom at least 12 in below undisturbed ground (IRC 2021 Section R403.1.4) and, where the ground freezes, below the frost line your jurisdiction sets in Table R301.2, unless the footing is protected from frost another way the code allows or sits on solid rock. The 6 in of the table is the footing's own thickness, not its depth.

    What else it is called

    Also searched as a concrete footing size calculator, a footing size chart or the footing size rule of thumb. The table assumes 9 ft walls, an 8 ft basement wall, a clear span roof and an interior bearing wall or beam at each floor. The footing projects at least 2 in past each face of the wall and no more than its own thickness (Section R403.1.1).

    The full IRC footing table

    IRC 2021 Table R403.1(1), minimum width and thickness of concrete wall footings for light-frame houses by load, stories, foundation and soil
    Load · stories · foundation1,500 psf soil2,000 psf soil2,500 psf soil3,000 psf soil3,500 psf soil4,000 psf soil
    20 psf roof live or 25 psf snow · 1 story · slab-on-grade 12 × 612 × 612 × 612 × 612 × 612 × 6
    20 psf roof live or 25 psf snow · 1 story · crawl space 12 × 612 × 612 × 612 × 612 × 612 × 6
    20 psf roof live or 25 psf snow · 1 story · basement 16 × 612 × 612 × 612 × 612 × 612 × 6
    20 psf roof live or 25 psf snow · 2 story · slab-on-grade 13 × 612 × 612 × 612 × 612 × 612 × 6
    20 psf roof live or 25 psf snow · 2 story · crawl space 15 × 612 × 612 × 612 × 612 × 612 × 6
    20 psf roof live or 25 psf snow · 2 story · basement 19 × 614 × 612 × 612 × 612 × 612 × 6
    20 psf roof live or 25 psf snow · 3 story · slab-on-grade 16 × 612 × 612 × 612 × 612 × 612 × 6
    20 psf roof live or 25 psf snow · 3 story · crawl space 18 × 614 × 612 × 612 × 612 × 612 × 6
    20 psf roof live or 25 psf snow · 3 story · basement 22 × 716 × 613 × 612 × 612 × 612 × 6
    30 psf snow · 1 story · slab-on-grade 12 × 612 × 612 × 612 × 612 × 612 × 6
    30 psf snow · 1 story · crawl space 13 × 612 × 612 × 612 × 612 × 612 × 6
    30 psf snow · 1 story · basement 16 × 612 × 612 × 612 × 612 × 612 × 6
    30 psf snow · 2 story · slab-on-grade 13 × 612 × 612 × 612 × 612 × 612 × 6
    30 psf snow · 2 story · crawl space 16 × 612 × 612 × 612 × 612 × 612 × 6
    30 psf snow · 2 story · basement 19 × 614 × 612 × 612 × 612 × 612 × 6
    30 psf snow · 3 story · slab-on-grade 16 × 614 × 612 × 612 × 612 × 612 × 6
    30 psf snow · 3 story · crawl space 19 × 614 × 612 × 612 × 612 × 612 × 6
    30 psf snow · 3 story · basement 22 × 716 × 613 × 612 × 612 × 612 × 6
    50 psf snow · 1 story · slab-on-grade 12 × 612 × 612 × 612 × 612 × 612 × 6
    50 psf snow · 1 story · crawl space 14 × 612 × 612 × 612 × 612 × 612 × 6
    50 psf snow · 1 story · basement 18 × 613 × 612 × 612 × 612 × 612 × 6
    50 psf snow · 2 story · slab-on-grade 15 × 613 × 612 × 612 × 612 × 612 × 6
    50 psf snow · 2 story · crawl space 17 × 613 × 612 × 612 × 612 × 612 × 6
    50 psf snow · 2 story · basement 21 × 715 × 612 × 612 × 612 × 612 × 6
    50 psf snow · 3 story · slab-on-grade 18 × 613 × 612 × 612 × 612 × 612 × 6
    50 psf snow · 3 story · crawl space 20 × 615 × 612 × 612 × 612 × 612 × 6
    50 psf snow · 3 story · basement 24 × 818 × 614 × 612 × 612 × 612 × 6
    70 psf snow · 1 story · slab-on-grade 14 × 612 × 612 × 612 × 612 × 612 × 6
    70 psf snow · 1 story · crawl space 16 × 612 × 612 × 612 × 612 × 612 × 6
    70 psf snow · 1 story · basement 19 × 614 × 612 × 612 × 612 × 612 × 6
    70 psf snow · 2 story · slab-on-grade 17 × 612 × 612 × 612 × 612 × 612 × 6
    70 psf snow · 2 story · crawl space 19 × 614 × 612 × 612 × 612 × 612 × 6
    70 psf snow · 2 story · basement 22 × 717 × 613 × 612 × 612 × 612 × 6
    70 psf snow · 3 story · slab-on-grade 20 × 615 × 612 × 612 × 612 × 612 × 6
    70 psf snow · 3 story · crawl space 22 × 716 × 613 × 612 × 612 × 612 × 6
    70 psf snow · 3 story · basement 24 × 819 × 615 × 613 × 612 × 612 × 6

    IRC 2021 Table R403.1(1), minimum width × thickness in inches of concrete footings for light-frame construction, as printed. The table assumes a 32 ft wide building, 9 ft walls and an 8 ft basement wall; note a allows interpolating the width between soil columns, never extrapolating; notes c and d add or take 2 in of width and 1 in of thickness for every 4 ft of building width over or under 32 ft, never under 12 × 6 in (Section R403.1.1).

    Where the numbers come from

    Table R403.1(1) is for light-frame walls. Brick veneer or lath and plaster go by Table R403.1(2), and concrete or masonry walls by Table R403.1(3), which this page does not read. A pier or column footing is sized by its tributary load instead, and for a deck post that is the deck footing calculator.

    By · Last updated . How this site is made.

    Other materials

    Embed this calculator

    Free to use on your own site. Copy the code and keep the credit line.

    Open the full calculator on YardsNeeded ↗